DLV-Ultra Battery Voltage Meter & Specific Gravity Testing Kit

In Stock

The DLV-Ultra Battery Testing Kit includes the DLV-Pro data logging voltmeter with the SG-Ultra or SG-Ultra Max digital hydrometer for a complete solution to specific gravity and battery voltage testing. The DLV-Pro measures and records cell voltages in less than 1 second, enabling rapid testing of battery cell voltages. Voltages are recorded in two formats: 8 strings of 256 or 20 strings of 48 readings. Specific gravity and temperature readings measured from the SG-Ultra or Ultra-Max are directly uploaded to the DLV Pro in 8 strings of 256 format. Both voltage and specific gravity readings can be combined into a single report.

The DLV-Ultra kit can also be used to perform a full discharge test on up to 256 cells by recording up to 11 time-stamped voltage readings for each cell, along with time-stamped load current readings and initial and/or final SG readings via the SG-Ultra. All test data can be uploaded to a PC using the included Winmeter 5.1 Battery Analysis Software.

Benefits

  • Record, view, & analyze cell voltage, SG, & temperature readings
  • Record voltage in either 8 strings of 256 or 20 strings of 48 format
  • Perform a full discharge test & analyze results on-site during the test
  • Easily transfer data files to Winmeter 5.1 battery analysis software
  • Export test data to PDF reports or Excel spreadsheets
  • Replay animated discharge tests

Own a device that needs service or annual calibration?

Submit an RMA >

Visit Eagle Eye University for information on our battery training courses.

 

Specifications

Measurement RangeVoltage: 0 – 20 VDC
Density: SG-Ultra: 0.000 – 2.000 g/cm3, SG-Ultra Max: 0.000 – 3.000 g/cm3
Sample Temperature: *0 – 80 °C (32 – 176 °F)
Viscosity: 0 – 1,000 mPa
AccuracyVoltage 0 – 4V: ± 5mV
Voltage 0 – 20V: ± 10mV
Density: 0.001 g/cm3
Temperature: ±0.2 °C (±0.4 °F)
ResolutionVoltage 0 – 4V: 1mV
Voltage 0 – 20V: 1mV
Density: 0.0001 g/cm3
RepeatabilitySG-Ultra Max: 0.0005 g/cm3
Test Speed1 second per cell
Minimum Sample VolumeSG-Ultra Max: 2 mL
Calibration MethodSG-Ultra Max: Automatic with distilled water
Display35 x 28 mm (1.4 x 1 in) color LED
Operating EnvironmentDLV-Pro Temperature: 0 – 40 °C (32 – 104 °F)
SG-Ultra Max Temperature: -10 – 50 °C (-15 – 122 °F)
Humidity: 0 – 80% (0-31°C) / 0 – 50% (32-40°C)
Power RequirementsSG-Ultra Max: (2) AA Batteries
DimensionsDLV-Pro: 165 x 76 x 33 mm (6.3 x 3 x 1.3 in)
SG-Ultra Max: 140 x 138 x 27 mm (5.5 x 5.4 x 1.0 in)
WeightDLV-Pro: 298 g (10.5 oz) SG-Ultra Max: 368 g (13 oz)
OptionsOption A: 8 Strings of 256 VDC, 8 Strings of 256 S.G., 20 Strings of 48 VDC
Option B: 20 Strings of 48 VDC, 20 Strings of 48 S.G.
 