LB-400-300kW/500kW-COM AC Load Bank

    LB-400-300kW/500kW-COM AC Load Bank by Eagle Eye Power Solutions, showcasing a durable steel frame with front-facing control panels, caster wheels for mobility, and advanced features for testing generators, UPS systems, and critical power applications with precision.
    LB-400/300KW-500KW COM AC Load Bank from Eagle Eye Power Solutions, featuring a robust steel enclosure with ventilation, caster wheels for portability, and advanced controls for precision testing of generators, UPS systems, and inverters in critical power applications.

    Automatic Load Bank Test Generator

    The LB-400-300kW/500kW-COM AC Load Bank and its accessories, including their function, performance, usage, and structure, provides users with a high-efficiency and reliable choice for a load bank test generator.

    Data Processing Software

    • Automatic load: User can set several periods of power and duration such as 0%→25%→50%→75%→100% or 110% then →75%→50%→25%→0%.etc. to make automatic load testing
    • Can make parallel testing for several units
    • Data can be saved, allowing both real-time display and history data
    • Charts and graphs can be exported as JPG file while testing data can be exported in Excel and Word format, and all can be printed

    Time for a Tune-up?

    If your device needs service or annual calibration let us help.

    Key Features

    • 3- line LED multi-function meter can display real-time voltage and current of three phase and each phase, resistive power, power factor, apparent power, frequency and running time of generator set
    • User can pre-set the power then press the master load button
    • Control mode: user can choose local control or intelligent control (through PC with our data management software)
    • Control mode interlock: there is switch in the control panel to choose control mode, other control mode is invalid if user chooses one control mode
    • Emergency stop button
    • In case of over-load, over-heat, or short circuit, load bank will automatically remove load and alarm
    • Fan protection: Load bank will not load before fan is on
    • Alarm will occur when any fan is abnormal or with insufficient air volume
    • Protection button: some protection buttons can be switched off for false alarm or special requirements

    Specifications

    Discharge Voltage RangeRange: 5 – 600V (Auto-Sensing)
    Discharge Current Range1 – 2000A
    Per Cell Voltage Type1 – 12V VRLA, VLA, NiCad, and more
    AccuracyDischarge Current: 0.1A / Voltage: 0.1V
    ResolutionDischarge Current: ±0.2A / Voltage: ±0.3%V
    Data TransferRS-232, USB
    DisplayBacklit numeric LED (CC) / 5” backlit LCD (D/S)
    Operating Environment0 – 40 °C (32 – 104 °F)
    Power Requirements110/220 VAC 50/60 Hz
    DimensionsSmall: 42 x 52 x 25 cm (16.5 x 20.5 x 9.8 in)
    Medium: 42 x 30 x 58 cm (16.5 x 11.8 x 22.8 in)
    Large: 48 x 30 x 65 cm (18.9 x 11.8 x 25.6 in)
    X-Large: 60 x 40 x 70 cm (23.6 x 15.7 x 27.5 in)
    XX-Large: 90 x 62 x 115 cm (35.4 x 24.4 x 45.2 in)
    XXX-Large: 145 x 90 x 87 cm (157 x 35.4 x 34.2 in)
    Weight
    Small: 22 kg (49 lbs)
    Medium: 26 kg (57 lbs)
    Large: 34 kg (75 lbs)
    X-Large: 54 kg (119 lbs)
    XX-Large: 170 kg (375 lbs)
    XXX-Large: 300 kg (662 lbs)
    *Sizes may vary from listed depending on model

    Resources & Support

    Product Literature

    Technical Information

    Support Documents

    Video Resources

    FAQs

    What are the typical applications for the LB-400 AC Load Bank?

    What power capacities are available for the LB-400 AC Load Bank?

    Can the LB-400 be used for continuous duty testing?

    Is the LB-400 portable or fixed?

    What kind of control system does the LB-400 AC Load Bank use?

    Does the LB-400 AC Load Bank include integrated safety systems?

    What input voltages does the LB-400 support?

    Can the LB-400 AC Load Bank load bank be customized for specific testing needs?

    Request Quote

    To top