Eagle Eye Power Solutions’ SLB-Series DC load testers are designed for ease of use, portability, and versatility in mind. Discharge testing batteries is the only verifiable method the capacity of your batteries and the SLB delivers a programmable, constant current load for your testing needs. Whether you are load testing for capacity, performance, acceptance, NERC compliance, or other, the SLB provides an economical complete package solution. Increase employee and battery system safety with PER CELL monitoring and standard built in auto-shutdown features. To suit a variety of industries and diverse applications, Eagle Eye Power Solutions offers over 75 standard models to fit your exact needs at the best price.
Key Features
- Safely monitor live tests remotely with wireless communication to the SLB load bank
- DataView software includes live monitoring, data recording, and report exporting to Microsoft Excel
- Discharge auto-shutdown for time duration, total string voltage, capacity, and individual cell voltage
- Parallel with another SLB-Series unit for increased discharge current capacity
- Assistant discharge feature allows for compatibility with existing non-SLB load banks
- Increase current and add individual cell monitoring to your existing equipment with SLB-Series
- Built-in circuit breakers for emergency shutdown and overload protection
- Optional: Real-time display of voltage for each cell/unit with DAC package for 1.2V, 2V, 6V, 12V cells
- Optional: Custom DAC packages available for monitoring of uncommon cell voltages and configurations
Specifications
Cell Voltage | Standard DAC: 1.2V1, 2V, 6V, 12V / Optional 3.6V, 4V, and other custom DAC configurations available upon request |
Discharge Current Range | Single Load: 12 – 600A / Parallel Load: Up to 1200A |
Discharge Voltage Range | Range: 10 – 576V (Max) / Voltage Steps: 12V, 24V, 36V, 48V, 80V, 125V, 240V, 380V, 480V |
Accuracy | Discharge Current: 1% / Voltage: 0.5% – 0.8% |
Resolution | Discharge Current: 0.1 A or 0.5% / Voltage: 0.001 V |
Sampling Interval | 5 seconds – 1 minute |
Data Transfer | USB, Wireless (466 MHz) |
Display | Backlit LCD |
Operating Environment | 0 – 40 °C (32 – 104 °F) |
Power Requirements | 110/220 VAC 50/60 Hz / DC (from connected batteries) |
Dimensions | Small: 400 x 177 x 288 mm (15.7 x 7 x 11.3 in) Medium: 520 x 202 x 355 mm (20.5 x 8 x 14 in) Large: 555 x 225 x 435 mm (22.5 x 8.9 x 17.2 in) X-Large: 603 x 400 x 740 mm (23.7 x 15.7 x 29 in) XX-Large: 762 x 406 x 737 mm (30 x 16 x 29 in) |
Weight | Small: 11 kg (24 lbs) Medium: 16 kg (36 lbs) Large: 21 kg (47 lbs) X-Large: 42 kg (93 lbs) XX-Large: 55 kg (122 lbs) |
Resources & Support
Product Literature
- SLB-Series Data Sheet
- SLB-Series DC Load Bank Case Study
- DC Load Bank Drop-In Specifications (SLB-Series)
- Benefits of SMART Load Testing
- DC Load Bank Series Comparison Chart
Technical Information
Support Documents
Video Resources
FAQs
What are some common applications areas for this product?
Common applications include but are not limited to:
- DC Generator Systems
- DC Battery Systems
- UPS Testing
- Rectifiers
- Power Supply
- Power Converter Units
- Standby Generators
- Diesel and Gas Turbines
- Micro-turbines
- Wind Generators
- Solar Arrays
- Electrical Distribution Systems
- Circuit Breakers
- Other Electrical and DC Power Supply Testing
Does the SLB-Series come with software?
Each SLB comes standard with Dataview software. This software allows us to live monitor, view test data, and export reports to Microsoft Excel
How is cell voltage monitoring accomplished?
The SLB-Series utilizes DACs (data acquisition cases) to connect to each cell. The DAC includes a wiring harness that connects to the cells. Each DAC communicates back to the SLB load bank wirelessly.
What is the power requirement for the SLB?
The exact power consumption of an SLB varies with model and discharge current, however expect the draw to be less than 9A at max current. A 15A circuit breaker is sufficient for power needs.
Common applications include but are not limited to:
DC Generator Systems
DC Battery Systems
UPS Testing
Rectifiers
Power Supply
Power Converter Units
Standby Generators
Diesel and Gas Turbines
Micro-turbines
Wind Generators
Solar Arrays
Electrical Distribution Systems
Circuit Breakers
Other Electrical and DC Power Supply Testing
Each SLB comes standard with Dataview software. This software allows us to live monitor, view test data, and export reports to Microsoft Excel
The SLB-Series utilizes DACs (data acquisition cases) to connect to each cell. The DAC includes a wiring harness that connects to the cells. Each DAC communicates back to the SLB load bank wirelessly.
The exact power consumption of an SLB varies with model and discharge current, however expect the draw to be less than 9A at max current. A 15A circuit breaker is sufficient for power needs.
Request Quote
Complete Your DC Power Solution
PRC-005-6 Battery Operation & Maintenance Compliance
Get trained by industry experts on how battery monitoring can help you meet and maintain compliance with NERC PRC-005-6.
BC-2500 Charger
Paired with a VIGILANT™ BMS, this resilient, redundant switch-mode charger will help you meet and maintain NERC PRC-005-6 and TPL-001-05 compliance.
VIGILANT™ Battery Monitor
Experience the revolutionary VIGILANT™ Battery Monitoring System, using advanced sensors and machine learning to predict battery condition. Monitors key parameters like voltage, current, and temperature.