TALON™ Nest – Rack Mounted AC Load Banks

Rack-Level Data Center Load Testing Before Server Deployment

    TALON™ SERIES – AC Load Banks

    Eagle Eye Power Solutions Talon Nest Load Bank - 3/4 View Back
    Eagle Eye Power Solutions Talon Nest Load Bank - Back
    Eagle Eye Power Solutions Talon Nest Load Bank- 3/4 View Right
    Eagle Eye Power Solutions Talon Nest Load Bank - Front

    TALON™ Nest Rack-Mounted AC Load Banks are engineered for rack-level data center load testing, commissioning, and thermal validation. Designed for standard server rack environments, TALON™ Nest applies controlled resistive loads up to 20kW to simulate server power demand and heat output before live IT equipment is installed.

    Data center teams use TALON™ Nest to validate rack power, UPS and PDU performance, branch circuits, airflow, and cooling systems under realistic operating conditions. This helps confirm electrical and thermal readiness before server deployment, during commissioning, or as part of ongoing power and cooling system verification.

    Each TALON™ Nest unit:

    • Is built for realistic white space testing in data center environments
    • Supports PDU validation and UPS testing
    • Is ideal for rack circuit loading and airflow studies
    • Enables HVAC performance verification
    • Has static fan models that provide fixed airflow for repeatable testing
    • Offers variable fan control adjustments of airflow and heat rejection
    • Helps simulate expected server operating conditions for more accurate testing and commissioning results

    TALON™ Nest Applications

    • Data center commissioning and integrated systems testing
    • Rack-level UPS and PDU validation
    • Branch circuit and breaker load testing
    • Simulated server load testing before IT equipment installation
    • Hot aisle / cold aisle airflow verification
    • Rack power density testing from 1–20kW
    • Load balancing across rack PDUs and panel-boards
    • Burn-in testing for new data halls or renovated white space
    • Capacity planning for future server deployments
    • Spot load testing during maintenance or troubleshooting
    • Thermal sensor and monitoring system verification
    • Factory acceptance testing for rack-level power systems
    • Temporary IT load simulation during migration or cutover projects

    Time for a Tune-Up?

    If your device needs service or annual calibration let us help.

    Key Features

    • Up to 20kW Rack-Level Loading:
      Simulates IT load for rack, PDU, UPS, and branch circuit validation.
    • Standard Rack-Mounted Design:
      Built for deployment in data center cabinets and aisle testing environments.
    • Static or Variable Fan Control:
      Supports fixed airflow testing or adjustable airflow to better match server thermal profiles.
    • Adjustable Load Step Control:
      Allows engineers to apply controlled heat load for staged commissioning, burn-in, and capacity testing.
    • Hot Aisle / Cold Aisle Validation:
      Helps verify airflow paths, temperature rise, rack density, and cooling system performance.
    • Integrated Protection System:
      Includes branch circuit protection, fan/load interlocks, airflow monitoring, over-temperature protection, over-voltage protection, E-stop, alarms, and chassis grounding.

    Specifications

    Nominal Voltage Rating
    240VAC Single Phase
    kW Models
    Up to 20kW
    Frequency
    60Hz
    Resolution
    Down to 1kW (depending on model)
    Cooling
    Forced air cooling
    Environmental
    -20 – 50°C (14 – 122°F), ≤95% RH, IP20 Rating
    Dimensions
    12U
    Weight
    Approximately 77 lbs.
    Power Connections
    C20 plugs; voltage and phase configuration confirmed by model and application.
    120, 240 or 120/240 Single Phase
    kW Models10, 30, 50, 75, 100, 125, 150 & 200 kW
    Frequency50/60 Hz
    Resolution1 kW
    ConfigurationSingle Phase
    Digital DisplayLCD multiple function display meter
    CommunicationRS-232/485, software package provided
    CoolingForced air
    Environmental-10 – 50°C (14 – 122°F), ≤95% RH
    ControlLocal panel control or laptop software control, RS-485 Modbus, dry contact terminal

    Resources & Support

    FAQs

    What is a rack-mounted AC load bank?

    What data center applications are TALON™ Nest rack-mounted AC load banks designed for?

    How does TALON™ Nest help with data center commissioning?

    Can TALON™ Nest simulate server heat load?

    What kW range is available for TALON™ Nest?

    Does TALON™ Nest fit in standard 19-inch server racks?

    Can TALON™ Nest be used for UPS and PDU testing?

    Can TALON™ Nest be used for hot aisle/cold aisle airflow testing?

    What safety features are included with TALON™ Nest?

    Can TALON™ Nest be controlled with software?

    What power connection options are available?

    What information is needed to quote a TALON™ Nest system?

    Request Quote

    To quote the correct configuration, Eagle Eye Power Solutions typically needs the required kW load, voltage, phase, plug or connection type, rack environment, airflow requirements, control method, quantity of units, and intended testing application.